R00D Air Booster Systems
2 to 1 Boost Ratio, 0-100 scfm flowrate
Our high flowrate air-driven, dual air pressure booster systems require no cooling water, lubrication or electricity. These boosters can deliver flowrates from zero to the values shown in the table below, and pressure boost ratios from zero to 2:1. The integral pressure regulator is used to set the maximum discharge pressure desired. The booster will maintain this pressure regardless of fluctuations in supply pressure. When there is no demand for high pressure air, the booster stalls and consumes no energy. It restarts automatically when there is demand.
»Frequently Asked Questions - FAQs
»Shipping Information
»Air Booster Repair Kits
Flowrate in SCFM | |||||||||||||||
Air Supply Pressure (psi) | Air Discharge Pressure (psi) | ||||||||||||||
60 | 70 | 80 | 90 | 100 | 110 | 120 | 130 | 140 | 150 | 160 | 170 | 180 | 190 | 200 | |
40 | 46 | 24 | 0 | ||||||||||||
60 | 83 | 70 | 52 | 30 | 0 | ||||||||||
80 | 100 | 88 | 74 | 57 | 37 | 0 | |||||||||
100 | 112 | 103 | 88 | 75 | 56 | 30 | 0 |
2:1 Dual Air Booster Systems

Model R00D • $4300
- 2:1 Dual Air Booster System
- 230 psi Maximum Pressure
- Aluminum Rail Mount - available in floor or wall mounted configurations
» Brochure
» Instructions
12 Gallon Tank

Model R12D • $6000
- 2:1 Dual Air Booster System
- 230 psi Maximum Pressure
- 12 Gallon Receiver Tank
» Brochure
» Instructions
(Replaces the GE001 and GF001 Models)
60 Gallon Tank

Model R60D • $8700
- 2:1 Dual Air Booster System
- 190 psi Maximum Pressure
- 60 Gallon Vertical Receiver Tank
» Brochure
» Instructions
(Replaces the GJ001 and GK001 Models)
For redundant dual boosters, see the R60Q.
System Options

Special Relief Valve: Option GC001 • $75
Replace standard 235 psi relief valve with a lower pressure valve.

Tank With Casters: Option C • $500
Adds 4 swivel casters (two are locking) to a tank allowing the system to be mobile.
Only available on 3.5 Gallon and 12 Gallon receiver tanks
Option C PDF

Secondary Filter/Regulator: Option D • $350
Adds a secondary filter/regulator to eliminate pulsations and maximize stored volume.
Option D PDF

Electronic Drain Valve: Option E • $300
Adds an electronic drain valve to automatically drain the tank in regular intervals.
Option E PDF

Safety Vent Valve: Option W • $450
Automatically vents air from booster and tank when supply air pressure is removed.
Option W PDF
View more products:
Air Pressure Booster Systems
• Gas Pressure Booster Systems
• Electric Inert Gas Pressure Booster Systems
• Repair Parts & Kits
• High Pressure Tanks